13/10
港鐵指,昨日下午5時許藍田站路軌旁懷疑因為短路,引致道岔設備一件絕緣膠起火。港鐵及消防人員隨即到場處理,列車服務在晚上約6時半恢復正常。
when an insulating rubber component in a track turnout caught fire (SCMP)
....
14/10
港鐵表示,今早的事故是由於藍田站的電力設備房,有電線過熱導致冒煙。至於昨晚就是由於道岔設備的絕緣膠短路起火,導致服務受阻。
港鐵車務工程維修副總監李劍雄指出,涉事起火的絕緣膠在今年9月已經進行檢測,亦在今年3月曾經進行更換。why?
hk01 video
潘焯鴻 fb ( doubtful analysis this time)
SER signal equipment room: facebook
波口: hkrail fandom
typical case:
mtr is using 1500 v dc on the tracks checkerboardhill
the arc/fire is likely between the trough wall and the metal rod above.
if it is insulator fire, is the insulator material ( nylon ? rubber?) is contaminated with (conductive) impurities. if it is contaminatedd during manufacturing, this can be worrying.
foreign conducting material is punctured into the insulator ?
visually the fire is white smoke and orange fire.
insulator material ( rubber, nylon, TPEE) gives out brown / black smoke when burnt. quite likely something else is burning. orange fire hints it is metallic (think flame test)
the faulty components analysis is most critical.
what test is done in last routine maintenance? visual? electrical insulation test ( megohm test)?
OTOH, whether 2 incidents are co - related, is not so important, as they are 10+ hours apart, and do NOT aggravate to a bigger and more damaging incident.
well, the second day incident is more serious, certainly there are a lot more equipment inside the room, and larger fire and/or damage if out of control.
insulator materials commonly in use
common causes of pcb short circuit - altium:
external contamination
internal CAF growth ( irrelavant here)
dirty / large solder paste / misalignment
worst case: uncaught design error
construction error - dimensions, insulator material choice